ALAN Electronic Systems -Medical
COMBI MAX MBXVP
ALAN Electronic Systems -Medical

Built on precision,
trusted by professionals.
ALAN exists because healthcare professionals deserve instruments they can depend on. We engineer diagnostic systems with the same rigour that surgeons bring to the operating theatre, understanding that accuracy in medicine is not negotiable.
- Engineered for reliability
- Trusted across Indian healthcare
- Standards that matter most
Features & Specifications
Maximum output of 400 Wattages in Monopolar Pure Cutting.
7 inchwide angle LCDtouchscreen for better view/usability.
199 User programmable memory locations to save profile and
preferred setting.
Audio-Visual indications of Error Messages, Instrument Open,
Instrument Short, Re-grasp&Ligated etc., on real-time basis.
Easy access to 5 different modes with just one single touch.
Unit can seal up to 7mmof vessel thickness in diameter.
7 different ligations levels for varied vessel thickness&results.
An efficient Bi-TUR systemfor all the Urological Applications.
Various Plasma Resection modes for different loop Sizes &
Shapes for applications like TURP, TCRE, TUVP, TUEB etc.
Dedicated 2 coagulationmodes for allUrological Applications.
Simultaneous Coagulation features with independent settings.
Special EndoCutmode for Polypectomy&Papillotomy.
User adjustable blend ratio from 10% – 90% in Monopolar.
Auto-Stop mode in Monopolar Coagulation for optimum result.
Auto Start/Stop in Bipolar for optimumcoagulation effect.
Lo&Hi Spray modes for non-contact superficial coagulation.
Randomized SprayON/OFF feature in Lo/Hi SprayModes.
Special Soft Mode for delicate tissues and Neurosurgery.
PPCM deactivates output power if it senses improper/less
contact between patient & return electrode to eliminate the risk
of patient burn.
Unit is compatible with Wired&Wireless Footswitch.
Unit can be upgraded with Argon Plasma Coagulation System.
Basic Construction in accordance with IEC standards.
Multiple micro-controller supervision for RF power accuracy.
Real time tissue impedance monitoring for power control.
Graphical representation of split/non-split patient plate contact quality.
Warnings and Errors are stored with timestamp for reviewing.
Built-in-line filter protects from voltage surges/bad line conditions.
Power up Self-Test to ensure unit healthiness.
Audio and Visual indication for easy interpretation.
Real-time Handswitch/Footswitch Short detection.
Works with input voltage of 110 VAC and 220 VAC.
PPCM – Patient Plate Contact Quality Monitoring System.
High Frequency Leakage monitoring and controlling system.
Autolock facility to prevent accidental change of settings.
Port ON/OFF control to prevent any accidental RF activation.
No power delivery if Patient Plate contact is less or insufficient.
Equipotential port for additional ground connection.
Type CF – Generator output is Floating (Isolated).
Convection cooling system to prolong unit’s life.
Pure :- 400 W
Lap Cut :- 300 W
Blend :- 250 W
Endo Cut :- 10 Levels.
Lo Spray :- 120 W
Hi Spray :- 70 W
Fulgurate :- 150 W
Lo Desiccate :- 120 W
Hi Desiccate :- 180 W
Soft :- 120 W
Auto Desiccate :- Auto
Auto Soft :- Auto
Randomized Spray Selections Available
Cut/Standard :- 120 W
Macro/Force :- 120 W
Micro/Precise :- 100 W
Auto Macro :- 120 W
Auto Micro :- 100 W
Auto Start / Stop
Input :- 220 / 230 VAC ± 20%,50Hz
Power Consumption :- 750VA Max.
Class :- I
Mdd. :- II B
Input Fuse :- 5 AT
Output Control :- 7” TFT Display with Touch Screen & Push buttons all Modes.
Nominal Freq. :- 360 / 550 KHz
Unit type :- CF
PER :- 98
Electrical Potential :- Connecting Pin and Balancing Indicated by Symbol.
Basic Construction :- In accordance with
IEC 60601-1
IEC 60601-1-2 &
IEC 60601-2-2
420mm (L)
380mm (W)
170mm (H)
8.0 kg. Maximum Weight.
RELIABILITY
- Basic Construction in accordance with IEC standards.
- Multiple micro-controller supervision for RF power accuracy.
- Real time tissue impedance monitoring for power control.
- Graphical representation of split/non-split patient plate contact quality.
- Warnings and Errors are stored with timestamp for reviewing.
- Built-in-line filter protects from voltage surges/bad line conditions.
- Power up Self-Test to ensure unit healthiness.
- Audio and Visual indication for easy interpretation.
- Real-time Handswitch/Footswitch Short detection.
SAFETY
- Works with input voltage of 110 VAC and 220 VAC.
- PPCM – Patient Plate Contact Quality Monitoring System.
- High Frequency Leakage monitoring and controlling system.
- Autolock facility to prevent accidental change of settings.
- Port ON/OFF control to prevent any accidental RF activation.
- No power delivery if Patient Plate contact is less or insufficient.
- Equipotential port for additional ground connection.
- Type CF – Generator output is Floating (Isolated).
- Convection cooling system to prolong unit’s life.
RF OUTPUT CHARACTERISTICS
MONOPOLAR CUT
- Pure : – 400 W
- Lap Cut : – 300 W
- Blend : – 250 W
- Endo Cut : – 10 Levels.
MONOPOLAR COAGULATION
- Lo Spray : – 120 W
- Hi Spray : – 70 W
- Fulgurate : – 150 W
- Lo Desiccate : – 120 W
- Hi Desiccate : – 180 W
- Soft : – 120 W
- Auto Desiccate : – Auto
- Auto Soft : – Auto
- Randomized Spray Selections Available
BIPOLAR
- Cut/Standard : – 120 W
- Macro/Force : – 120 W
- Micro/Precise : – 100 W
- Auto Macro : – 120 W
- Auto Micro : – 100 W
- Auto Start / Stop
TECHNICAL DATA
- Input : – 220 / 230 VAC ± 20%,50Hz
- Power Consumption : – 750VA Max.
- Class : – I
- Mdd. : – II B
- Input Fuse : – 5 AT
- Output Control : – 7” TFT Display with Touch Screen & Push buttons all Modes.
- Nominal Freq. : – 360 / 550 KHz
SAFETY STANDARDS
- Unit type : – CF
- PER : – 98
- Electrical Potential : – Connecting Pin and Balancing Indicated by Symbol.
- Basic Construction : – In accordance with
- IEC 60601-1
- IEC 60601-1-2 &
- IEC 60601-2-2
DIMENSION
- 420mm (L)
- 380mm (W)
- 170mm (H)
WEIGHT
- 8.0 kg. Maximum Weight.