ALAN Electronic Systems -Medical
Special Soft Mode for delicate /soft tissues and Neurosurgery.
ALAN Electronic Systems -Medical

ALAN exists because healthcare professionals deserve instruments they can depend on. We engineer diagnostic systems with the same rigour that surgeons bring to the operating theatre, understanding that accuracy in medicine is not negotiable.
Maximum output of 400 Wattages in Monopolar Pure Cutting.
7 inch wide angle LCD touchscreen for better view/usability.
User adjustable blend ratio from 10% – 90% in Monopolar.
Special EndoCut mode for Polypectomy & Papillotomy.
Simultaneous Coagulation features with independent settings.
Lo & Hi Spray modes for non-contact superficial coagulation.
Randomized Spray ON/OFF feature in Lo/Hi Spray Modes.
Auto-Stop mode in Monopolar Coagulation for optimum result.
Auto Start – Auto Stop in Bipolar for optimum coagulation effect.
User adjustable delay in Auto-Start mode from 0.1/9.9 seconds.
199 User programmable memory locations to save profile and preferred setting.
Audio-Visual indications of Error Messages, Instrument Short, Hand/Footswitch Error, Time-Out Error etc on real-time basis.
Restores previous activated settings during Power Up/Restart.
PPCM (Patient Plate Contact Monitoring System) deactivates output if it senses improper connection or less contact between patient and return electrode to eliminate risk of Patient Burns.
Unit is compatible with Wired Footswitch/Wireless Footswitch.
Well suited for General/Gynaec/Underwater Applications etc.
Unit can be upgraded with Argon Plasma Coagulation System Vessel Sealing System and Bipolar Saline TUR.
Basic Construction n accordance with IEC i standards.
Multiple micro-controller supervision for RF power accuracy.
Real time tissue impedance monitoring for power control.
Graphical split/non-split patient representation of plate contact . quality
Warnings Errors stored with timestamp for and are reviewing.
Built-in-line filter protects from voltage surges/bad line conditions.
Power up Self-Test to ensure unit healthiness.
Audio and Visual indication for easy interpretation.
Real-time Handswitch/Footswitch Short detection.
Works with input voltage of 110 VAC and 220 VAC.
PPCM – Patient Plate Contact Quality Monitoring System.
High Frequency Leakage monitoring and controlling system.
Autolock facility to prevent accidental change of settings.
Port ON/OFF control to prevent accidental RF any activation.
No power delivery if Patient Plate contact is less or insufficient.
Equipotential port for ground connection. additional
Type CF – Generator output is Floating (Isolated).
Convection cooling system rolong unit’s life.
Pure :- 400 W
Lap Cut :- 300 W
Blend :- 250 W
Endo Cut :- 10 Levels.
Lo Spray :- 120 W
Hi Spray :- 70 W
Fulgurate :- 150 W
Lo Desiccate :- 120 W
Hi Desiccate :- 1 0 W 8
Soft :- 120 W
Auto Desiccate :- Auto
Auto Soft :- Auto
Randomized Spray Selections Available
Cut/Standard :- 120 W
Macro/Force :- 120 W
Micro/Precise :- 100 W
Auto Macro :- 120 W
Auto Micro :- 100 W
Ligate :-5 Levels
F-Ligate :-2 Levels
Low Cut :- 250 W
Hi Cut-1 :- 300 W
Hi Cut- :- 300 W 2
Hi Cut- :- 300 W 3
Effect 1 :- 300 W –
Effect :- 300 W
Desiccate :- 250 W
Force :- 200 W
Input :- 220 / 230 VAC ± 20%,50Hz
Power Consumption :- 750VA Max.
Class :- I
Mdd. :- II B
Input Fuse :- 5 AT
Output Control :- 7” TFT Display with Touch Screen Push buttons all & Modes.
Nominal Freq. :- 360 / 550 KH
Unit type :- CF
PER :- 98
Electrical Potential :- Connecting Pin and Balancing Indicated by Symbol.
Basic Construction :- In accordance with
IEC 60601-1
IEC 60601-1-2 &
IEC 60601-2-2
420mm (L)
380mm (W)
170mm (H)
8 kg Max Weight .0 . imum .
ALAN Electronic Systems -Medical
Special Soft Mode for delicate /soft tissues and Neurosurgery.
Connect with our team about ALAN’s solutions